FIRMWARE CHANGES 30493: - Added support for special variable UseMWHFromPrimary - Fixed Nexus 1450 MWH overflow - Changed Gain test StepDuration units to use ms 30013: - Increased the timeout for FCR communications warning to 25ms - Fixed a problem that caused the second half of the FcrOutputs object words to be swapped - Added Nexus 1450 support 29984: - Fixed handling of ADADIO IRQ Abort and BIST that could cause delayed measurements - Added support to FCR communication map version 2 (fuses, temperatures, status, etc.) 29514: - Added Profibus protocol output for Operation ShadowMode in Base+5D bit 14 (just after SpareBlocking2) 29412: - Added input Operation.ShadowMode bit to indicate when the regulator is working in shadow (1) or normal (0) 29295: - Added support for Concurrent CPU - Disable NCC when Bottom Limit Switch is active - Added RegStatus ControlPowerProgramPercent (400673) and ControlSmartARCPercent (400674) for Modbus map publishing - Fixed alarm timing problem for PLC Not active, SmartARC not active, Local I/O fault and Short Electrode. Real timing was triple the configured unless a user saved the AlarmLimits model - Fixed FiringCircuitReplacement unable to reconnect after trying 120 times. - Updated documentation: RegStatus ControlPowerProgramPercent and ControlSmartARCPercent; Operation.ChargePowerOnTime_Offset units and divisor; SmartARCSupport.* divisors 28281: -Added FCR Modbus Address Offset 26077: - Updated the Dynamic NCC logic, now supports DynNCCMinPressure, DynNCCMaxPressure and EnableNCCDynamicOffline special variables - Fixed End of charge input from SmartARC 25597: - Fixed the Nexus reconnection logic, it stopped trying after a long unsuccessful period 25299: - AutoLower has a delayed start (OnDelay) - AutoLower overrides the Vsp & Isp 24834: - Fixed incorrect fatal error. 24330: - Fixed memory corruption occurring when an HMI was closed or lost its connection, and a user saves the model in the FurnaceType screen. 23611: - Added UseFastRaise, Speed and Ramp properties to ShaperGains __________________________________________________________________________________________ HMI CHANGES 30462: - Fixed potential problem with HMI time display - Fixed potential error in Event screen that could make it unresponsive the first time it was opened - Changed Gain test StepDuration units to use ms - Updated DC documentation to include FCR version 2 variables 30309: - Fixed problem handling some timezones 30059: - Added FCR Overview and FCR Status screens when FCR communication is version 2 29995: - Added support to FCR communication map version 2 (fuses, temperatures, status, etc.) - Added performance heat report fields ControlSmartARCPercent, ControlPowerProgramPercent, ControlManualPercent summary variables - Fixed Power Program field VLimit that was not displayed and could not be changed - Fixed font scaling problem when resizing the HMI - Fixed bad scaling of heat trends chart in Performance Heat Report for cultures that use comma as decimal point - Added validation to VmeIOConfiguration model for duplicate channel names, numbers or missing channels 29484: - Fixed Menu button Power Curves that was inserted by mistake 29473: - Added support for hiding the HMI when operating in Shadow mode and showing it when being active (General Settings), useful when there are multiple controllers 29297: - Updated documentation: RegStatus ControlPowerProgramPercent and ControlSmartARCPercent; Operation.ChargePowerOnTime_Offset units and divisor; SmartARCSupport.* divisors 29031: - Fixed IOConfiguration voltage divider R2 control that was being hidden incorrectly on single electrode furnaces 28280: - Added Electrical System - FCR Modbus Address Offset 26223: - Fixed online help and updated Auto Lower text and images - Fixed bug that caused exported files miss columns containing tag or id, like Voltage - Added missing AdvancedControlProfile column to Heat Report 25993: - Added balance column to statistics dialog - Fixed a potential model corruption in the model Undo button - Fixed External Data loading issues 25680: - Improved the Electrode Tests information gathering to prevent incomplete test packagess. 25481: - Fixed display Dynamic NCC Setpoint scale. The scale adjustment depends on Min and Max pressures at the Analog Inputs. - Improvement at Proxy Service, after save Network Settings the service is reconfigured automatically in order to let other services (Trends & HMI) communicate with QNX. 25299: - Added CurrentSetpoint and ActionDelay to AutoLower Model Isp and OnDelay added. - Screen layout improved. Units labels corrected. - ReSized the Color Boxes for selecting the color of the trend - Improved upgarde time to be applied 23812: - Fixes to LEDs (Auto, JS Raise, JS Lower) on twin shells without independent electrodes - Added Invert setting to Encoder channel - Fixed bug in Furnace Type that prevented it from being saved 23611: - Shaper Screen - Speed, Ramp and enable checkbox for FastRaise - Spanish translation - Shaper Screen - Speed, Ramp and enable checkbox for FastRaise